DM6210 8-Channel RTD Signal Converter RS485 Relay DIN Rail 24V
$40.48
$80.56
Description ️ DM6210 8-Channel RTD Signal Converter – PT100 / PT1000 / Cu50 / Cu100, RS485 MODBUS, Relay Output, DIN Rail, 24VDC | AuscomTech The DM6210 8-Channel RTD Signal Converter is an industrial-grade temperature measurement and control module designed for multi-point RTD monitoring in automation, HVAC, energy, and process control systems.This stocked version fully supports RTD sensors including PT100, PT1000, Cu50, and Cu100, and integrates RS485 MODBUS-RTU communication, relay outputs, and an onboard display in a compact DIN-rail enclosure. Ideal for PLC and SCADA systems requiring reliable, accurate, and electrically robust temperature acquisition. ⭐ Key Features ️ Full RTD Sensor Support (In-Stock Version)Compatible with PT100, PT1000, Cu50, and Cu100 RTD sensors for flexible temperature measurement across multiple standards. 8 Independent Measurement ChannelsMonitor up to 8 RTD inputs simultaneously with high-resolution sampling. RS485 Communication (MODBUS-RTU)Isolated RS485 interface with lightning protection ensures stable communication in noisy industrial environments. Relay Outputs for Alarms & ControlIntegrated relay outputs allow direct triggering of alarms, interlocks, or control devices based on temperature thresholds. ️ LED / LCD DisplayClear display shows real-time channel data for quick on-site monitoring. ️ Onboard Configuration ButtonsSet parameters, alarms, ranges, and communication settings directly on the unit. DIN-35 Rail Mount DesignCompact housing designed for easy installation in industrial control panels. ️ Industrial Electrical ProtectionHigh insulation resistance, dielectric strength, and overload protection for long-term reliability. Technical Specifications General Model: DM6210 Input Type: RTD (PT100 / PT1000 / Cu50 / Cu100) Number of Channels: 8 A/D Resolution: 16-bit Measurement Accuracy: ±0.2% FS Conversion Speed: ~0.3 s per channel Power Consumption: < 4 W Power Supply DC Supply: 10–30V DC (24VDC typical) Outputs Relay Output: AC 220V / 5A Analog Outputs (model dependent): 4–20mA / 0–10mA / 0–20mA (≤250Ω) 1–5V / 0–5V / 0–10V (≥200kΩ) Communication Interface: RS485 Protocol: MODBUS-RTU Baud Rate: 1.2k – 57.6 kbps Environmental Operating Temperature: −10°C to 60°C Operating Humidity: <85% RH Insulation Resistance: >100MΩ (500VDC) Dielectric Strength: 1000VDC Compatible With • PLC systems• SCADA and DCS platforms• Industrial HMIs• HVAC control systems• Process automation equipment• Energy and utility monitoring systems Typical Applications • Multi-point temperature monitoring• Industrial process control• HVAC and building automation• Equipment over-temperature protection• Alarm and safety systems• Utilities and infrastructure monitoring ⚠️ Important Notes • This stocked unit supports RTD sensors only (PT100 / PT1000 / Cu50 / Cu100)• Thermocouple input versions are available by special order• Use a regulated 24VDC supply for best performance Package Includes • 1 × DM6210 8-Channel RTD Signal Converter
Signal Converters